Menampilkan 441–450 dari 12101 artikel
IMPLEMENTATION OF DIABETES MELLITUS HANDLING PROTOCOLS IN GERIATRIC PATIENTS AT PANTI DHARMA BAKTI KASIH SURAKARTA
Vioneery, Deoni
; Fitriyani, Noor
; Listrikawati, Martini
; Dewi Listiyanawati, Mutiara
; Dirhan, Dirhan
MEDIKA TRADA : Jurnal Teknik Elektomedik Polbitrada
Vol 6
, No 2
(2025)
Diabetes mellitus (DM) is one of the chronic diseases that often occurs in the elderly population, especially in nursing homes. The management of DM in geriatric patients requires a special approach that takes into account their physical, psychological, and social conditions. This study aims to analyze the implementation of the DM management protocol for geriatric patients at the Wonogiri Nursing Home and to identify its impact on blood sugar control and patients' quality of life. The study empl...
Sumber Asli
Google Scholar
DOI
Design Of Phantom Ultrasonography For Ultrasonography (USG) Calibration
MEDIKA TRADA : Jurnal Teknik Elektomedik Polbitrada
Vol 6
, No 2
(2025)
This study aims to design and build an Ultrasonography (USG) Phantom as an ultrasound calibration medium with more affordable materials but still meets quality and precision standards. The USG Phantom is designed using two basic materials, namely distilled water and engine oil, to then compare its performance in producing ultrasonic images. The research method used is an experiment with the stages of tool design, phantom manufacturing, and functional testing using Vertical and Horizontal Distanc...
Sumber Asli
Google Scholar
DOI
Workload Analysis Medical Record Unit at Roemani Muhammadiyah Hospital Semarang 2025 Using the NASA-TLX Method
MEDIKA TRADA : Jurnal Teknik Elektomedik Polbitrada
Vol 6
, No 2
(2025)
The Medical Records Unit plays a crucial role in ensuring the completeness and accuracy of patient information in hospitals. A high workload in this unit can impact Performance and service quality. One of the factors that triggers workload is the transition process from a manual system to Electronic Medical Records (EMR), as occurred at Roemani Muhammadiyah Hospital in Semarang City. This study aims to analyze the workload level of Medical Records Unit staff using the NASA-TLX method, which asse...
Sumber Asli
Google Scholar
DOI
DESIGN OF ELECTRIC CAUTERY SURGICAL INSTRUMENT BASED ON ARDUINO
MEDIKA TRADA : Jurnal Teknik Elektomedik Polbitrada
Vol 6
, No 2
(2025)
The development of electromedical technology encourages the creation of safer and more efficient surgical tools, one of which is electric cautery. This study aims to design and build an electric cautery prototype based on an Arduino Uno microcontroller equipped with a Liquid Crystal Display (LCD) to display current (0–6 A) and frequency (0–50 Hz) parameters in real-time. The research method uses a Research and Development (R&D) approach, starting from the design stage, prototyping, to functi...
Sumber Asli
Google Scholar
DOI
Design of Fetal Doppler Simulator for Fetal Doppler Calibration
MEDIKA TRADA : Jurnal Teknik Elektomedik Polbitrada
Vol 6
, No 2
(2025)
The Fetal Doppler Simulator for calibration is a device designed to ensure the accuracy and reliability of Fetal Doppler equipment in monitoring fetal heart rate. Traditionally, calibration of Fetal Doppler devices has relied on limited methods with relatively high costs. Therefore, an alternative calibration medium that is more economical, practical, and reliable is needed. This simulator functions by generating fetal heartbeat signals with various rhythm patterns, ranging from normal condition...
Sumber Asli
Google Scholar
DOI
Analysis of Infusion Pump Accuracy with Domestic Component Level Using Uncertainty Method
MEDIKA TRADA : Jurnal Teknik Elektomedik Polbitrada
Vol 6
, No 2
(2025)
Component-Level Domestic Content Policy (TKDN) encourages the utilization of domestically produced medical devices; however, their accuracy and safety must be proven. This study aims to analyze the accuracy of domestic infusion pumps using the uncertainty measurement method. A total of four units from four brands (Endo, ESA Tech, Inmedik, and Krisma Care) were tested on the flow rate parameter with variations of 10, 50, 100, 200, and 300 mL/hour. Each test point was measured six times using a ca...
Sumber Asli
Google Scholar
DOI
Comparative Performance Analysis of Imported vs. Local NIBP Simulators against Blood Pressure Monitor Using Uncertainty Method
MEDIKA TRADA : Jurnal Teknik Elektomedik Polbitrada
Vol 6
, No 2
(2025)
Calibration of non-invasive blood pressure (NIBP) devices is essential to ensure measurement accuracy in healthcare services. This study aims to compare the performance of two calibrators, XB1000 and Multisim, in testing two NIBP units using the uncertainty analysis method. Measurements were conducted on systolic, diastolic, and heart rate parameters with a total of 16 data points per parameter. The results show that XB1000 achieved a lower total average expanded uncertainty (U95) of 0.421 mmHg...
Sumber Asli
Google Scholar
DOI
Accuracy Analysis of Oxygen Saturation Measurements of TKDN Oximeters Using the Uncertainty Method
MEDIKA TRADA : Jurnal Teknik Elektomedik Polbitrada
Vol 6
, No 2
(2025)
This study aims to evaluate the accuracy and effectiveness of several domestic pulse oximeter brands (Elitech, Kaltech, and Endo) and a foreign brand (GE), calibrated using the Prosim SPOT Light SpO₂ Pulse Oximeter Tester. This quantitative study involved three domestically produced oximeters and one imported unit. The oxygen saturation setpoints were varied at 80%, 85%, 90%, 95%, 97%, 98%, 99%, and 100%, with three repetitions for each. Data analysis was conducted using the GUM Uncertainty Meth...
Sumber Asli
Google Scholar
DOI
Design of Monitoring System for Temperature, Humidity, Smoke, Fire, Wind Speed and Wind Direction based on SMS in UNTIRTA's Farm
MEDIKA TRADA : Jurnal Teknik Elektomedik Polbitrada
Vol 6
, No 2
(2025)
Farm fires are a major cause of agricultural loss, leading to the destruction of millions of hectares of farmland. In Indonesia alone, the financial losses due to farm fires were estimated at 221 trillion rupiah in 2015. This study proposes the development of an early fire detection and environmental monitoring system that integrates MQ-7 and photodiode sensors for smoke and fire detection, along with additional sensors for monitoring temperature, humidity, wind speed, and wind direction. The sy...
Sumber Asli
Google Scholar
DOI
Implementation of pancasila values on moral education and children's character in the COVID-19
Jurnal Global Citizen : Jurnal Ilmiah Kajian Pendidikan Kewarganegaraan
Vol 14
, No 2
(2025)
The purpose of writing this article is to find out and strengthen character and moral formation through the application of Pancasila values in children, where in this era of digital media development, the moral development of children whose daily lives are closely related to the digital world is greatly influenced. The method used in this research is qualitative, based on a literature study technique that collects a lot of information from previous research. The results of this study indicate th...